Glass Tube Inclined Manometer

Introduction to Pitambara Engineering Glass Tube Inclined Manometer

Pitambara Engineering is a leading manufacturer of precision industrial measurement tools, recognized for their high-quality and reliable products. Among their innovative solutions is the Glass Tube Inclined Manometer, a precision instrument designed for accurately measuring low-pressure differences in gases and liquids. This manometer is widely used in applications where high accuracy, reliability, and clear visibility of readings are crucial.


What is a Glass Tube Inclined Manometer?

The Glass Tube Inclined Manometer is a differential pressure measuring device that uses a transparent glass tube as its main component. The inclined design amplifies sensitivity, enabling precise detection of low-pressure variations. The glass construction ensures chemical resistance, durability, and exceptional clarity for observing the liquid column displacement.


Key Features of Pitambara Engineering Glass Tube Inclined Manometer

  1. High-Precision Design:
    • The inclined configuration enhances measurement sensitivity, allowing accurate detection of minute pressure differences.
    • Suitable for applications where precision is paramount.
  2. Durable Glass Tube Construction:
    • The use of high-quality glass ensures resistance to chemicals, corrosion, and temperature variations.
    • Provides clear and unobstructed visibility of the fluid column for precise readings.
  3. Easy-to-Read Scale:
    • Equipped with a finely calibrated and well-marked scale for interpreting pressure readings.
    • Ensures accurate results even in challenging environments.
  4. Versatility:
    • Capable of measuring both positive and negative (vacuum) pressure.
    • Compatible with various working fluids such as water, oil, or mercury, depending on the application.
  5. Simple and Reliable Operation:
    • Operates on fundamental physical principles, requiring no external power or complex electronics.
    • Low maintenance due to its simple construction and lack of moving parts.

Working Principle

The Glass Tube Inclined Manometer functions based on hydrostatic pressure principles. When pressure is applied, the liquid in the glass tube moves, with its displacement corresponding to the pressure differential. The inclined orientation allows for a longer measurement scale, improving the resolution for small pressure changes. The pressure difference is read directly from the graduated scale on the instrument.


Applications

  • HVAC Systems: For monitoring airflow and pressure in ductwork and ventilation systems.
  • Industrial Processes: Measuring pressure drops in filters, orifice plates, and pipelines.
  • Laboratories: Ideal for experiments requiring accurate low-pressure measurement.
  • Environmental Monitoring: Measuring differential pressures in air quality and atmospheric studies.

Advantages of the Glass Tube Inclined Manometer

  • Superior Accuracy: The inclined design ensures precise readings, especially for low-pressure ranges.
  • Chemical Resistance: Glass tubes resist corrosion and chemical interactions, extending the instrument’s lifespan.
  • Cost-Effective Solution: Offers accurate and reliable results with minimal maintenance costs.
  • Eco-Friendly Operation: No need for electricity or batteries, ensuring a sustainable measuring solution.
  • Clear Visual Feedback: Glass construction provides excellent clarity for easy monitoring.

The Pitambara Engineering Glass Tube Inclined Manometer is a dependable tool, delivering consistent performance across industrial, scientific, and environmental applications. Its robust design, combined with high accuracy, makes it an invaluable device for professionals seeking reliable low-pressure measurement solutions.

Would you like additional details on customization, specifications, or installation procedures?

  • Precautions for installation
  • Applications
  • Features
  • During installation, tank shuld be completely empty.
  • There should be no objects which shall hinder the float.
  • Ensure that the float position inside the tank should be such that agitation on it will be minimum.
  • The position of mounting nozzle should be far away from the liquid fill pipe to protect the float from damage and faulty readings due to turbulence.
  • Ensure that tank structures / fittings do not come in the way of calibrated gauges boards
  • Instruments required- Welding machine, combination/crimping plier, spanner and adjustable.
  • Even with large changes in liquid density, the immersion of a large diameter float will change very little, thus density has little effect on accuracy.
  • Float systems are simple and easily understood.
  • Even if the primary requirement is the transmitted signal, local indicators can continue to operate, even on loss of power.
  • Simple
  • Low Maintenance
  • Economical Measurement Solution
  • Easy Mounting
  • Assured Level Indication without power supply